Advertisement!
Author Information Pack
Editorial Board
Submit article
Special Issue
Editor's selection process
Join as Reviewer/Editor
List of Reviewer
Indexing Information
Most popular articles
Purchase Single Articles
Archive
Free Online Access
Current Issue
Recommend this journal to your library
Advertiser
Accepted Articles
Search Articles
Email Alerts
FAQ
Contact Us
Indian Journal of Dental Education

Volume  12, Issue 1, Jan-Mar 2019, Pages 11-16
 

Original Article

Evaluation of Linear Dimensional Accuracy of Conventional Heat Cure Resin and Microwave Cured Resin: A Comparative Study

Pawan Kumar1, Savita Akki2, Mahesh Suganna3, Pankaj Datta4, Aruna DS5, Sonia Datta6

1Professor, Department of Prosthodontics, Al-Badar Dental College and Hospital, Kalburgi, Karnataka 585102, India. 2Associate Professor, Department of Dentistry. Bidar Institute of Medical Sciences, Bidar, Karnataka 585401, India. 3Professor & Head, Mithila Minority Dental College & Hospital, A Post Graduate Institute, Darbhanga, Bihar 846001, India. 4Dean, Professor & Head, Department of Prosthodontics, 6Associate Professor, Department of Public Health Dentistry, Inderprastha Dental College & H

Choose an option to locate / access this Article:
90 days Access
Check if you have access through your login credentials.        PDF      |
|

Open Access: View PDF

DOI: DOI: https://dx.doi.org/10.21088/ijde.0974.6099.12119.2

Abstract

Objective: The use of microwave energy has been used in various fields of dentistry, medicine and household appliances. Recently microwave energy has been successfully used in dentistry and plethora of articles has been published. Also included in the field of sterilization, disinfection of dental appliances, drying of gypsum product and polymerization of resin. The objective of this study was to compare the linear dimensional accuracy of conventional heat cure resin to microwave cure resin. Method: In this study a standard metal die as per ADA specification NO 12 measuring 65 mm in length,3 mm thickness,10 mm wide was used to plan 30 test specimens. 15 test specimens were prepared from conventional heat cure resin and 15 from microwave cured resin. The specimens were checked and evaluated using digital caliper which has precision of ±0.001 mm. The measurements were compared recorded with standard metal dies. Result and conclusion: Linear dimensional accuracy was checked both between and within the group with the ANOVA test and found that accuracy between the groups was 0.148 and 0.004 within the group of the study. Consequently the liner dimensional accuracy of microwave resin were better-quality and advanced to conventional cure resin with p value of 0.000.

Keywords: Denture Base Resins; Conventional Heat Cure Resin; Microwave Cure Resin; Linear Dimensional Accuracy; Polymerization; Metal Dies.


Corresponding Author : Pankaj Datta