Advertisement!
Author Information Pack
Editorial Board
Submit article
Special Issue
Editor's selection process
Join as Reviewer/Editor
List of Reviewer
Indexing Information
Most popular articles
Purchase Single Articles
Archive
Free Online Access
Current Issue
Recommend this journal to your library
Advertiser
Accepted Articles
Search Articles
Email Alerts
FAQ
Contact Us
Indian Journal of Anesthesia and Analgesia

Volume  6, Issue 3, May-June 2019, Pages 990-996
 

Original Article

A Comparative Evaluation of Respiratory Mechanics with I-Gel or ProSeal LMA as Airway Device in Laparoscopic Surgeries

Salini R.Varma1, Biju ML2

1Senior Resident, Department of Neuroanaesthesia, Sree Chitra Tirunal Institute of Medical Sciences and Technology, Thiruvananthapuram, Kerala 695011, India, 2Associate Professor, Department of Anaesthesia, DM Wayanad Institute of Medical Sciences (DM WIMS) and Aster Speciality Hospital, Wayanad, Kerala 673577, India.

Choose an option to locate / access this Article:
60 days Access
Check if you have access through your login credentials.        PDF      |
|

Open Access: View PDF

DOI: http://dx.doi.org/10.21088/ijaa.2349.8471.6319.42

Abstract

Objectives: The study was designed to compare the respiratory mechanics of the patients with either I-Gel or ProSeal LMA as airway device during positive pressure ventilation while undergoing laparoscopic hernia repair surgeries. The other parameters compared are ease of insertion and airway trauma. Methodology: This randomized control study was conducted in our tertiary care hospital. 110 patients of ASA PS class 1-2 were randomly divided into 2 groups of 55 each. Premedication and anesthesia technique were standardized in both the groups. One group had PLMA as their airway device and the other group had I-gel as their airway device. We compared the respiratory mechanics (dynamic compliance, airway resistance and peak airway pressure) of these patients during positive pressure ventilation. The other parameters compared were ease of insertion and airway trauma. Results: I-Gel is a better device compared to PLMA in terms of dynamic compliance, peak airway pressure, airway resistance and ease of insertion was higher with PLMA. There was no significant difference in blood staining after removal of the device or trauma to lips, tongue and teeth between two groups. Conclusion: From our study, we concluded that I-Gel is a better device compared to PLMA in terms of dynamic compliance, peak airway pressure, airway resistance and ease of insertion. There was no significant difference in blood staining after removal of the device or trauma to lips, tongue and teeth between two groups.


Keywords : I-gel; Proseal LMA; Laparoscopic hernia repair; Compliance; Resistance; Peak airway pressure.
Corresponding Author : Biju M L