Volume  7, Issue 3, May-June 2020, Pages 703-709
 

Original Article

Sonoclot Analyzer Guided Transfusion Therapy in Patients Undergoing On-Pump Cardiac Surgeries

Khan Afroz Shahana M, Vaishali A Mohod, Quazi Mohammed Azhar

1 Assistant Professor, 2 Associate Professor, Department of Anaesthesia and Critical Care, 3Associate Professor, Department of Plastic Surgery, Grant Government Medical College, Mumbai, Maharashtra 400008, India

Choose an option to locate / access this Article:
90 days Access
Check if you have access through your login credentials.        PDF      |
|

Open Access: View PDF

DOI: http://dx.doi.org/10.21088/ijaa.2349.8471.7320.7

Abstract

Context: The study was conducted to establish a co-relation between Sonoclot parameters and blood and blood product during on-pump cardiac surgeries.

Aims: To estimate the amount of blood and blood
product transfusion and post-operative drain are affected by Sonoclot-guided transfusion therapy.

Settings
and Design: Randomised controlled Study

Methods and Material: Total of 120 patients were randomly assigned
by computer generation to either Sonoclot guided therapy or routine hospital therapy. Patients of either sex undergoing on-pump complex cardiac surgical procedures. Patients having pre-existing hepatic disorders, a renal disease requiring dialysis, and those who received anticoagulant or antiplatelet drugs within one week of surgery were excluded.

Statistical analysis used: Data were analyzed using descriptive statistics to get the frequency distribution & the Independent Sample T-test was used for inter-group Comparison. p-value of <0.05 is considered as statistically significant. SPSS (Statistical Software for Social Sciences) version 20 was used.

Results: The whole blood transfusion in the two groups was non-significant both intra-operative and post-operative period. While a comparison of FFP transfusion during an intra-operative period in Sonoclot group was significant. Platelets were administered in the post-operative period and comparison in the two groups was not significant. A comparison of 24 hr drain output in two groups of patients was non-significant.
Conclusions: It allows the diagnosis of an exact cause of hemostatic abnormality i.e. deficiency of coagulation factors or fibrinogen or platelet function.


Keywords : Point of care test, Sonoclot, Transfusion, On-pump cardiac surgeries.
Corresponding Author : Vaishali A Mohod