Advertisement!
Author Information Pack
Editorial Board
Submit article
Special Issue
Editor's selection process
Join as Reviewer/Editor
List of Reviewer
Indexing Information
Most popular articles
Purchase Single Articles
Archive
Free Online Access
Current Issue
Recommend this journal to your library
Advertiser
Accepted Articles
Search Articles
Email Alerts
FAQ
Contact Us
Indian Journal of Anesthesia and Analgesia

Volume  7, Issue 1, January-February 2020, Pages 99-105
 

Original Article

A Prospective Observational Study on Ultrasonographic Measurement of Optic Nerve Sheath Diameter as a Bedside Tool in Detecting Findings of Increased Intracranial Pressure in Neuro Critical Care Patients

Ravi Saravanan, Krishnamoorthy Karthik, Kanirajan Yogalakshmi, Prabhuvel Nandhini

1,2Associate Professor, 3Post Graduate, Department of Anaesthesiology, SRM Medical College Hospital and Research Centre, Potheri, Chennai, Tamil Nadu 603203, India. 4Consultant, Department of Anaesthesiology, SIMS Hospital, Vadapazhani, Chennai, Tamil Nadu 600026, India.

Choose an option to locate / access this Article:
60 days Access
Check if you have access through your login credentials.        PDF      |
|

Open Access: View PDF

DOI: http://dx.doi.org/10.21088/ijaa.2349.8471.7120.15

Abstract

Context: Posttraumatic intracranial hypertension might be detrimental. Bedside ultrasound measurement of optic nerve sheath diameter helps in early diagnosis of increased intracranial pressure.

Aims: To determine the accuracy of detecting the raised intracranial pressure by ultrasonographic measurement of Optic Nerve Sheath Diameter (ONSD). To correlate ONSD with the Computer Tomography (CT) findings of increased intracranial pressure and the average time taken to measure ONSD with ultrasound.

Settings and Design: A Prospective, double blinded Observational Study.

Methods and Materials: To determine the accuracy of detecting the raised intracranial pressure by ultrasonographic measurement of Optic Nerve Sheath Diameter (ONSD). To correlate ONSD with the Computer Tomography (CT) findings of increased intracranial pressure and the average time taken to measure ONSD with ultrasound. Statistical Analysis: Descriptive Analysis - Sensitivity, Specificity and Predictive values.

Results: The sensitivity for the mean binocular optic nerve sheath diameter ultrasonography in detecting elevated intracranial pressure was 99.42% and the specificity was 82.43% with an odds ratio of 0.3547. The positive predictive value was 92.97% and the negative predictive value was 98.39% with an p - value of < 0.0001 which was significant. The average time taken to measure the ONSD was 19.8 secs.

Conclusions: The evaluation of optic nerve sheath diameter is a simple noninvasive procedure, which is a potentially useful tool in the assessment and monitoring of raised intracranial pressure.

 


Keywords : Bedside ultrasound; Optic nerve sheath diameter; Intracranial hypertension.
Corresponding Author : Krishnamoorthy Karthik