Advertisement!
Author Information Pack
Editorial Board
Submit article
Special Issue
Editor's selection process
Join as Reviewer/Editor
List of Reviewer
Indexing Information
Most popular articles
Purchase Single Articles
Archive
Free Online Access
Current Issue
Recommend this journal to your library
Advertiser
Accepted Articles
Search Articles
Email Alerts
FAQ
Contact Us
Indian Journal of Pathology: Research and Practice

Volume  6, Issue 2 (Part-2), APRIL - JUNE 2017, Pages 421-426
 

Original Article

Does Sample Collected in Plain Vial Provides Better Results Than Anticoagulated Blood in the Antiglobulin Test?

Siddhartha Shanker Sinha*, Pooja Jaiswal*, Yogesh Kumar Yadav**, Sonal Saxena***, Nausheen S. Khan*

*Assistant Professor, Department of Pathology **Lecturer, Department of Pathology, Government Medical College, Kannauj, Uttar Pradesh, India.***Assistant Professor, Department of Dentistry, Integral Institute of Medical Sciences and Research, Lucknow

Choose an option to locate / access this Article:
90 days Access
Check if you have access through your login credentials.        PDF      |
|

Open Access: View PDF

DOI: DOI: http://dx.doi.org/10.21088/ijprp.2278.148X.62(pt-II)17.14

Abstract

Context: The antiglobulin test is an important test in the detection of immunoglobulin or complement bound on the surface of red blood cells (RBC) and serum antibodies. It is possible that anticoagulants used for collection of blood samples may affect the end result of this test. Aim: To study the variation in degree of agglutination between the antiglobulin test performed on plain blood and anticoagulated blood. Settings and Design: Antiglobulin Test was performed on blood samples collected from umbilical cord of 100 new-born babies during delivery in plain vials and vials with anti-coagulant like ethylenediaminetetraacetic acid (EDTA) and citrate. Methods and Materials: 6 ml of blood samples were collected from umbilical cord immediately after delivery and 2 ml each transferred into: EDTA, Citrate and Plain vials. The sample thus collected was used for performing the direct antiglobulin test. 10% red cell suspension was sensitized with Anti D IgG (as supplied by Tulip diagnostics) at different dilutions of 1/10, 1/20, 1/30 and 1/40. The washed saline suspension of RBC’s is treated with Anti- human globulin serum and agglutination is observed under a microscope at 5X bjective. The picture is taken of microscopic field using MIPS (micro image processing system) and saved Statistical Analysis used: Friedman test and Wilcoxon signed-rank test. Results: The degree of agglutination at various dilutions obtained by using plain blood samples was found to be higher than that obtained by using anticoagulated blood. The citrated blood samples gave intermediate agglutination results between blood samples collected in plain and EDTA vials.

Keywords: Antiglobulin Test; Agglutination; EDTA; Citrate.


Corresponding Author : Pooja Jaiswal